Lock-up is the last look inside the walls. A Maddingley inspection found insulation not yet in, wall wrap missing and bracing cut. Why that matters in a cold climate home.

Ballarat 3350 · 2 June 2026

In short: In Ballarat's climate zone 7, insulation decides how a house feels for its whole life. Lock-up is the only stage you can see it all.

What lock-up means

Roof on, windows and external doors in, external walls closed. Plaster has not started, so the frame, insulation and services are still visible.

Insulation and wrap

On a Maddingley lock-up inspection in February 2026 the wall and ceiling insulation was not yet installed, insulation was missing from the wall between garage and house, and wall wrap was incomplete between the two.

Why it matters in Ballarat

The NCC puts Ballarat in climate zone 7, cool temperate. Missing batts, compressed insulation and gaps in wrap mean cold walls, condensation risk and higher heating bills for the life of the house.

Bracing and noggings

Bracing that has been cut to fit services weakens the frame against wind. Missing noggings around the bath hob and in the garage ceiling show up later as cracked plaster or nowhere to fix a door motor.

Carried over items

Lock-up is also when we recheck frame items. On this job several were still open.

Booking it right

Book once the external envelope is closed and before plasterboard is delivered. Ask the builder to confirm insulation will be in place, or arrange to recheck it.

Written by our local inspection team from work carried out in Ballarat. Licensed building practitioners, Building & Plumbing Commission registration CDB-U 53425.

Guides

More new construction stage inspections guides for Ballarat

All guides →

Book a building inspection in Ballarat

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Ballarat owners ask about this

Is insulation checked at lock-up?

Where it is installed, yes. If it is not yet in, we note it and recommend a check before plaster.

What R values apply?

Those in your energy rating and building documents. We check what is installed against them where labels are visible.

Can cut bracing be repaired?

Usually, as the builder or engineer specifies.

Do you check electrical rough-in?

No. Electrical work is inspected by a licensed electrician.